How simple would it be to automatically turn on your fan based on temperature changes? All you need to do is set a trigger temperature for when the fan should activate or deactivate. The W1209 module, which is highly functional and cost-effective, can help you create this impressive home automation!

The W1209 thermostat module includes a temperature sensor, buttons, an LED display, and a relay, requiring a DC 12V power supply. It is an affordable and reliable thermostat controller. Thermostats are devices that monitor the temperature of a system to maintain it at a desired set point or close to it. The NTC temperature sensor enables the module to intelligently control various electrical devices based on temperature. An NTC thermistor has a negative temperature coefficient, meaning its resistance decreases as the temperature rises.

The W1209 features an embedded microcontroller, so minimal programming knowledge is needed. The module includes three switches for configuring parameters, including the ON and OFF trigger temperatures. The relay can handle voltages up to a maximum of 240V AC at 5A or 14V DC at 10A. The temperature is displayed in degrees Celsius on a 7-segment display, and the relay's state is indicated by an LED on the W1209 module.

W1209 Module SPECIFICATIONS:-

  • Temperature Control Range: -50 ~ 110 C
  • Resolution at -9.9 to 99.9: 0.1 C
  • Resolution at all other temperatures: 1 C
  • Measurement Accuracy: 0.1 C
  • Control Accuracy: 0.1 C
  • Refresh Rate: 0.5 Seconds
  • Input Power (DC): 12V
  • Measuring Inputs: NTC (10K 0.5%)
  • Waterproof Sensor: 0.5M
  • Output: 1 Channel Relay Output,
  • Capacity: 10A

Power Consumption:-

  • Static Current: <=35mA
  • Current: <=65mA

Environmental Requirements:-

  • Temperature: -10 ~ 60 C
  • Humidity: 20-85%

Dimensions:-

  • 48mm x 40mm x 14mm


Settings Chart:-

  • Long press the “SET” button to activate the menu.
  • Code Description Range Default Value
  • P0 Heat C/H C
  • P1 Backlash Set 0.1-15 2
  • P2 Upper Limit 110 110
  • P3 Lower Limit -50 -50
  • P4 Correction -7.0 ~ 7.0 0
  • P5 Delay Start Time 0-10 mins 0
  • P6 High-Temperature Alarm 0-110 OFF
  • Long pressing +- will reset all values to their default

Working:-

Current temperature will be displayed on the module in degree Celsius by default. When switched to a different mode, inactivity for approximately 5 seconds would lead to restoring the value of the module to the default temperature display.


Setting Modes:-

Trigger Temperature:Press “SET” button on the module and current temperature will be displayed on the screen. Using “+” and “-“ button, one can set the temperature in 0.1 degrees (Celsius) increments. No activity for 2 seconds will result in setting and storing the trigger temperature and then the screen will display the current temperature.

Parameters Setting:-

Pressing the “SET” button for a minimum of 5 seconds will lead to the setting of the parameter present in the module. The seven segment display will start with the display of first parameter “P0”. Pressing ‘ + ’ or ‘ - ‘ buttons will help to go to parameters (P0-P6). Pressing “SET” button midst the parameters will let you change the value for that parameter. After setting the required parameter, press set button to exit that option. If no button is pressed for 5 seconds the thermostat will exit the parameter option and will return back to the default temperature.

Heating Parameter P0: P0 has two settings, C and H. The default setting C can be used to connect to an air-conditioner as the relay energizes when the temperature is reached. Setting H leads to de-energizing the relay when the required temperature is detected. It can be used to control any heating device.

Hysteresis Parameter P1: This parameter sets the range of change in temperature that must occur before relay will change state.

Parameter P2 (Upper Limit Temperature): P2 limits the maximum trigger temperature that can be set. It acts as a safety feature that stops the user to set an extremely high trigger temperature.

Parameter P3 (Lower Limit Temperature): P3 limits the minimum trigger temperature that can be set. It also acts as a safety feature that stops the user to set a low triggering temperature.

Offset Correction Parameter P4: Changes can be made if there is a difference between the displayed temperature and actual temperature reading with this parameter.

Delay Parameter P5: Delay in the switching of the relay when the trigger temperature has reached, can be set by the help of delay parameter P5. It can be set in one-minute increments up to a maximum of 10 minutes.

Alarm Parameter P6: This parameter causes the relay to switch off when the temperature reaches its settings. The display will show ‘ --- ‘ to indicate an alarm condition. The relay will not re-energize until the temperature falls below this value.

 

* Product Images are shown for illustrative purposes only and may differ from actual product.

 

 

How simple would it be to automatically turn on your fan based on temperature changes? All you need to do is set a trigger temperature for when the fan should activate or deactivate. The W1209 module, which is highly functional and cost-effective, can help you create this impressive home automation!

The W1209 thermostat module includes a temperature sensor, buttons, an LED display, and a relay, requiring a DC 12V power supply. It is an affordable and reliable thermostat controller. Thermostats are devices that monitor the temperature of a system to maintain it at a desired set point or close to it. The NTC temperature sensor enables the module to intelligently control various electrical devices based on temperature. An NTC thermistor has a negative temperature coefficient, meaning its resistance decreases as the temperature rises.

The W1209 features an embedded microcontroller, so minimal programming knowledge is needed. The module includes three switches for configuring parameters, including the ON and OFF trigger temperatures. The relay can handle voltages up to a maximum of 240V AC at 5A or 14V DC at 10A. The temperature is displayed in degrees Celsius on a 7-segment display, and the relay's state is indicated by an LED on the W1209 module.

W1209 Module SPECIFICATIONS:-

  • Temperature Control Range: -50 ~ 110 C
  • Resolution at -9.9 to 99.9: 0.1 C
  • Resolution at all other temperatures: 1 C
  • Measurement Accuracy: 0.1 C
  • Control Accuracy: 0.1 C
  • Refresh Rate: 0.5 Seconds
  • Input Power (DC): 12V
  • Measuring Inputs: NTC (10K 0.5%)
  • Waterproof Sensor: 0.5M
  • Output: 1 Channel Relay Output,
  • Capacity: 10A

Power Consumption:-

  • Static Current: <=35mA
  • Current: <=65mA

Environmental Requirements:-

  • Temperature: -10 ~ 60 C
  • Humidity: 20-85%

Dimensions:-

  • 48mm x 40mm x 14mm


Settings Chart:-

  • Long press the “SET” button to activate the menu.
  • Code Description Range Default Value
  • P0 Heat C/H C
  • P1 Backlash Set 0.1-15 2
  • P2 Upper Limit 110 110
  • P3 Lower Limit -50 -50
  • P4 Correction -7.0 ~ 7.0 0
  • P5 Delay Start Time 0-10 mins 0
  • P6 High-Temperature Alarm 0-110 OFF
  • Long pressing +- will reset all values to their default

Working:-

Current temperature will be displayed on the module in degree Celsius by default. When switched to a different mode, inactivity for approximately 5 seconds would lead to restoring the value of the module to the default temperature display.


Setting Modes:-

Trigger Temperature:Press “SET” button on the module and current temperature will be displayed on the screen. Using “+” and “-“ button, one can set the temperature in 0.1 degrees (Celsius) increments. No activity for 2 seconds will result in setting and storing the trigger temperature and then the screen will display the current temperature.

Parameters Setting:-

Pressing the “SET” button for a minimum of 5 seconds will lead to the setting of the parameter present in the module. The seven segment display will start with the display of first parameter “P0”. Pressing ‘ + ’ or ‘ - ‘ buttons will help to go to parameters (P0-P6). Pressing “SET” button midst the parameters will let you change the value for that parameter. After setting the required parameter, press set button to exit that option. If no button is pressed for 5 seconds the thermostat will exit the parameter option and will return back to the default temperature.
Heating Parameter P0: P0 has two settings, C and H. The default setting C can be used to connect to an air-conditioner as the relay energizes when the temperature is reached. Setting H leads to de-energizing the relay when the required temperature is detected. It can be used to control any heating device.
Hysteresis Parameter P1: This parameter sets the range of change in temperature that must occur before relay will change state.
Parameter P2 (Upper Limit Temperature): P2 limits the maximum trigger temperature that can be set. It acts as a safety feature that stops the user to set an extremely high trigger temperature.
Parameter P3 (Lower Limit Temperature): P3 limits the minimum trigger temperature that can be set. It also acts as a safety feature that stops the user to set a low triggering temperature.
Offset Correction Parameter P4: Changes can be made if there is a difference between the displayed temperature and actual temperature reading with this parameter.
Delay Parameter P5: Delay in the switching of the relay when the trigger temperature has reached, can be set by the help of delay parameter P5. It can be set in one-minute increments up to a maximum of 10 minutes.
Alarm Parameter P6: This parameter causes the relay to switch off when the temperature reaches its settings. The display will show ‘ --- ‘ to indicate an alarm condition. The relay will not re-energize until the temperature falls below this value.

 

* Product Images are shown for illustrative purposes only and may differ from actual product.

 

Shipping Policies

  • To ensure that your order reaches you in the fastest time and in good condition, we only ship through reputed courier agencies.
  • While we shall strive to ship all items in your order together, this may not always be possible due to product characteristics, or availability. However, we will inform you before doing it.
  • If you believe that the product is not in good condition, or if the packaging is tampered with or damaged, before accepting delivery of the goods, please refuse to take delivery of the package, and call our Customer Care +919659361116 or Contact us, mentioning your order reference number. We shall make our best efforts to ensure that a replacement delivery is made to you at the earliest.
  • You may track the shipping status of your order on our website, by clicking at Track your Order section.
  • Please note all items (including gifts) will be shipped with an invoice mentioning the price, as per Indian Tax Regulations.

Shipping Partners

  • We use FedEx, Aramex, Professional Services to ship our products to your destination as available during checkout and chosen by you.
  • We also can ship through EMS Speed post on special request to remote locations, if you think that our shipping partners do not have coverage or served you improperly. HOWEVER, WE CAN’T GUARANTEE TO COMPLY TO YOUR REQUEST. This is due to the reason each shipment content is being verified by the post office before accepting. If they feel that the item may be damaged, then they will not accept the shipment.

Shipping Time / Delivery Time

  • We make our best efforts to ship your order within the same day of the order. 99% of our orders are shipped within 24 Hours.
  • We ship on weekdays (Monday to Saturday), excluding public holidays. Orders placed on SUNDAY will be shipped only on MONDAY
  • Orders placed before 4.00 PM will be shipped on the same day except on Sundays and Public Holidays.
  • Shipments through FedEx / Aramex/ Professional Services, if created before 04:00 PM will be picked up by them on the same day. Otherwise, the shipment will be picked up only on the next day.
  • Though we can guarantee a delivery time of 2-5 days to anywhere in India, it is totally beyond our control. Each shipping companies have their own methods, intermediate transit locations, etc. and the delivery time is not predictable.
  • Please plan your order allowing sufficient time for the delivery instead of last-minute orders.

Guarantee/Warranty

All items are delivered with a standard warranty of minimum 15 days (unless otherwise specified in the product page) to protect the customers from any manufacturing defect. If you have any problems with your order, please notify us within this duration from the date of shipment of any defective product. You agree to pay for the return shipping on exchanges and returns and we will reimburse this cost upon verification of a defect with the product. We will replace or repair the damaged products at free of cost with shipping prepaid by us. In case, we do not have the product in stock to provide a replacement, we will issue a 100% refund. Furthermore, no warranty will apply if the Product has been subject to misuse, static discharge, neglect, accident, modification, or has been soldered or altered in any way.

To the product need to be exchanged, firstly, please send the photos of damaged products to us. We will estimate the damages then decide the best way to exchange or return the product. If the particular item is not in stock to replace, we will provide the full refund.

100% Refund/Replacement

We guarantee to provide accurate descriptions and high-quality product as mentioned in the website. In order to protect customers from shipping damage, item mismatch or parts missing, etc., we are providing 2 days time (From the date of order delivery) to report the complaint by going to my account section and then to your order, you will find an option for Request Refund. Our technical team will verify the submitted details visually and will issue RMA number to return the material. Once we received the product our experts will verify the issue reported and will send the replacement items to the customer shipping cost prepaid by us. In case, we do not have the product in stock to provide a replacement, we will issue a 100% refund. Furthermore, no warranty will apply if the Product has been subject to misuse, static discharge, neglect, accident, modification, or has been soldered or altered in any way. Due to the nature of the products we are selling and our strict quality policy, we are unable to offer order cancellation and return without a valid reason. ROBODIUM reserves the right to take the final decision on all refund request.

Changing or Canceling An Order

Need change something about your order or just want it canceled? You can ask us (by Email Only ) to change the items on your order, update an address or payment method, or just cancel it. Customer Service will get back to you by email within one business day regarding your request. Only orders that are still in status “Pending” or “Payment Verification” can be altered or canceled. If your order has already moved to a different status, you won’t be able to alter it or cancel it. In some cases, Order cancellation may attract 5% bank charges depending on the payment methods used by the customer. (It is because most of payment gateway providers collect their Commission even though order canceled and refunded.).Due to the nature of the products we are selling and our strict quality policy, we are unable to offer order cancellation and return without a valid reason. ROBODIUM reserves the right to take the final decision on all refund request.

Return Guidelines

Once we confirmed the faulty item cannot be repairable by the customer or by Remote Desktop (Team Viewer), we will issue the RMA Number, which you have to mention clearly on Shipping boxes. Do not write anything on the merchandise packaging (Product package). Defective unused merchandise will be replaced within 2 days of receipt. All returns must include a copy of the original packing list that came with your shipment.

Limits Of Responsibility

We accept no responsibility for improper installation of our products. Electrical polarity must be properly observed in hooking up electrical components.